Publicación:
DEGRADABILITY OF ECF KRAFT EFFLUENT BY A CATECHOL-DRIVEN FENTON REACTION

Imagen por defecto
Fecha
2018
Título de la revista
ISSN de la revista
Título del volumen
Editor
FRESENIUS ENVIRONMENTAL BULLETIN
Proyectos de investigación
Unidades organizativas
Número de la revista
Resumen
THE DEGRADATION OF A HIGHLY LOADED ECF (ELE- MENTAL CHLORINE FREE) KRAFT MILL EFFLUENT WAS STUDIED AND OPTIMIZED USING A CATECHOL (CAT) DRIVEN FENTON REACTION IN A LAB-SCALE FOR 2 H AT ROOM TEMPERATURE USING A RESPONSE SURFACE METHODOLOGY BASED ON A CIR- CUNSCRIBED CENTRAL COMPOSITED DESIGN (CCC). OPTI- MAL COD REMOVAL WAS ACHIEVED AT: CATECHOL 150 ?M.; FE(III) 800 ?M; H 2 O 2 12000 ?M ; PH 2.5. AT THESE OPTIMAL REACTION CONDITIONS, TOC (TOTAL OR- GANIC CARBON), AOX (ADSORBABLE ORGANIC HALOGENS) AND ACUTE TOXICITY WERE DETERMINED AS WELL. COD, TOC, AND AOX REMOVALS ACHIEVED BY THE CAT DRIVEN FENTON REACTION WERE SIMILAR TO THOSE OB- TAINED BY CONVENTIONAL AND FENTON TYPE REACTIONS (40% REMOVALS, MEAN VALUE, IN ALL CASES). HOWEVER, THE ACUTE TOXICITY INCREASED DURING THE CAT DRIVEN FEN- TON REACTION AND THE CONVENTIONAL AND FENTON TYPE REACTIONS. THESE RESULTS SUGGEST THAT THE CAT DRIVEN FENTON REACTION WOULD BE A MORE SUITABLE METHOD FOR EFFLUENT OXIDATION (AS A TERTIARY TREATMENT). FOR A FEA- SIBLE APPLICATION, WE SUGGEST TO IMMOBILIZE CAT, OR TO USE IT AS A SOLID PHASE WITH ANCHORED CATECHO
Descripción
Palabras clave
Citación