Publicación: SIMULATION OF THE INFLUENCE OF THE RADIAL GRADED POROSITY DISTRIBUTION ON ELASTIC MODULUS OF / PHASE TI-BASED ALLOY FOAMS FOR BONE IMPLANT
dc.creator | GUILHERME OLIVEIRA NEVES | |
dc.date | 2023 | |
dc.date.accessioned | 2025-01-10T15:44:20Z | |
dc.date.available | 2025-01-10T15:44:20Z | |
dc.date.issued | 2023 | |
dc.description.abstract | THIS RESEARCH AIMS TO EXAMINE HOW A RADIAL GRADED POROSITY DISTRIBUTION AFFECTS THE ELASTIC MODULUS BY CONDUCTING SIMULATIONS ON TI-BASED ALLOY FOAMS WITH FACE-CENTERED CUBIC AND BODY-CENTERED CUBIC CRYSTAL STRUCTURES. FOUR TYPES OF FOAMS WERE ANALYZED; COMMERCIALLY PURE-TI, TI-13TA-6MN (TTM), TI-13TA-(TT) AND TI-13TA-6SN (TTS), (ALL IN AT.%). FOUR RADIAL GRADED POROSITY DISTRIBUTION CONFIGURATIONS WERE MODELED AND SIMULATED USING THE FINITE ELEMENT ANALYSIS (FEA). THE RADIAL GRADED POROSITY DISTRIBUTION CONFIGURATIONS WERE GENERATED USING A MATERIAL DESIGNER (ANSYS) WITH A PORE RANGE OF 200 TO 600 ?M. THESE RADIAL GRADED POROSITY DISTRIBUTIONS HAD AVERAGE POROSITY VALUES OF 0, 20, 30 AND 40%. THE CONSOLIDATED SAMPLES THAT WERE OBTAINED THROUGH A POWDER METALLURGY TECHNIQUE IN TWO STEP SAMPLES WERE SYNTHESIZED USING A POWDER METALLURGY TECHNIQUE, WITH THE ELASTIC MODULI VALUES OF THE AFOREMENTIONED TI BASED ALLOYS BEING MEASURED BY ULTRASOUND USING ~110, ~69, ~61 AND ~65 GPA, RESPECTIVELY. THE RESULTS SHOWED THAT THE MODULUS DECREASED AS A FUNCTION OF POROSITY LEVEL IN ALL SIMULATED MATERIALS. THE TTM, TT AND TTS FOAMS, WITH AVERAGE POROSITIES OF 20, 30 AND 40%, EXHIBITED AN MODULUS SMALLER THAN 30 GPA, WHICH IS A REQUIREMENT TO BE USED AS A BIOMATERIAL IN HUMAN BONES. THE TT FOAMS SHOWED THE LOWEST MODULUS WHEN COMPARED TO THE OTHER FOAMS. FINALLY, CERTAIN THEORETICAL MODELS WERE USED TO OBTAIN THE MODULUS, THE BEST BEING; THE GIBSON?ASHBY MODEL (? = 1 AND N = 2.5) FOR THE CP-TI FOAMS AND KNUDSEN?SPRIGGS MODEL (B = 3.06) FOR THE TTM, TT AND TTS FOAMS. | |
dc.format | application/pdf | |
dc.identifier.doi | 10.3390/ma16237320 | |
dc.identifier.issn | 1996-1944 | |
dc.identifier.issn | 1996-1944 | |
dc.identifier.uri | https://repositorio.ubiobio.cl/handle/123456789/13429 | |
dc.language | spa | |
dc.publisher | MATERIALS | |
dc.relation.uri | 10.3390/ma16237320 | |
dc.rights | PUBLICADA | |
dc.subject | Ti-based alloys | |
dc.subject | simulation | |
dc.subject | radial graded porosity | |
dc.subject | foam | |
dc.subject | elastic modulus | |
dc.title | SIMULATION OF THE INFLUENCE OF THE RADIAL GRADED POROSITY DISTRIBUTION ON ELASTIC MODULUS OF / PHASE TI-BASED ALLOY FOAMS FOR BONE IMPLANT | |
dc.type | ARTÍCULO | |
dspace.entity.type | Publication | |
ubb.Estado | PUBLICADA | |
ubb.Otra Reparticion | DEPARTAMENTO DE INGENIERIA MECANICA | |
ubb.Sede | CONCEPCIÓN |