Análisis teórico-experimental de uniones híbridas en una columna prefabricada de hormigón armado

dc.contributor.advisorOpazo Vega, Alexander I.es
dc.contributor.authorCisterna Marchant, Ricardo Andrés -- cisterna.ing@gmail.com
dc.contributor.authorJara Crua, Vicente Gaspar
dc.contributor.editorUniversidad del Bío-Bío. Departamento de Ingeniería Civil y Ambiental (Chile)es
dc.date.accessioned2018-01-26T12:39:19Z
dc.date.available2018-01-26T12:39:19Z
dc.date.issued2016
dc.descriptionMemoria (Ingeniero Civil) -- Universidad del Bío-Bío. Concepción, 2016.es
dc.description.abstractDentro de las tipologías constructivas más utilizadas en estructuras industriales, destacan los pórticos prefabricados de hormigón armado. No obstante, diversas investigaciones han demostrado que este tipo de estructuras pueden quedar con daños y deformaciones remanentes, luego de eventos sísmicos importantes. Para controlar estos daños se desarrolló el concepto de uniones híbridas, donde se combinan propiedades de auto-centrado y disipación de energía, a partir del uso de cables post-tensados sin adherencia y barras longitudinales de acero dúctil no pretensadas. El sistema de uniones híbridas se ha utilizado anteriormente en otros países, sin embargo, en Chile aún no se ha validado su comportamiento para un elemento real construido. Es por ello, que el propósito de este trabajo es analizar el comportamiento teórico-experimental de una columna con uniones híbridas. A través de modelaciones numéricas se simulará el ensayo prueba de carga a columna realizado por CITEC UBB, y así obtener teóricamente la respuesta de la unión hibrida. Al comparar estas respuestas teóricas y experimentales de la unión, se observó que las curvas teóricas disipan mayor energía que las experimentales. Esto podría deberse principalmente a los métodos de análisis empleados y a parámetros constructivos.es
dc.description.abstract-2Precast reinforced gantries stand out within constructive typology in industrial structures. Nevertheless, diverse studies have shown this kind of structures can get seriously damaged and with remaining deformation afterwards important seismic events. In order to control these damages, the concept of Hybrid Joints was developed, where auto-centring and power dissipation get combined from the use of Post-Tensioned Tendons without adhesion and non prestressed Mild Steel longitudinal bars. The Hybrid Joints system has been used in some countries; however, its performance on a real constructed element has not been validated in Chile. Due to this fact, the purpose of this research was to analyse the theoretical and experimental performance of a column with Hybrid Joints. The column load test was simulated through numerical modelling by CITEC UBB in order to theoretically get the response of the Hybrid Joint. By comparing these theoretical and experimental responses, it was found that theoretical curves dissipate more energy than the experimental ones, which could mainly be due to the methods of analysis used and to constructive parameters.
dc.description.call-numberM(DC) 624 C497 2016es
dc.identifier.urihttp://repobib.ubiobio.cl/jspui/handle/123456789/2213
dc.language.isoeses
dc.subjectUNIONES HIBRIDAS-INVESTIGACIONESes
dc.subjectHORMIGON PREFABRICADO-INVESTIGACIONESes
dc.subjectCABLES POST-TENSADOSes
dc.subjectACERO DUCTILes
dc.subjectDISIPACION DE ENERGIAes
dc.subjectHYBRID JOINTes
dc.subjectPOST-TENSIONED TENDONSes
dc.subjectMILD STEELes
dc.subjectPOWER DISSIPATIONes
dc.titleAnálisis teórico-experimental de uniones híbridas en una columna prefabricada de hormigón armadoes
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Cisterna_Marchant_Ricardo_Andres.pdf
Tamaño:
1.84 MB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: