Ventilación natural y calidad del aire en espacios de urgencia de centros de salud

dc.contributor.advisorTrebilcock Kelly, Maureen Eileenes
dc.contributor.advisorArias Jiménez, Nelson Manueles
dc.contributor.authorArriagada Soto, Javiera Paz
dc.contributor.editorUniversidad del Bío-Bío. Facultad de Arquitectura, Construcción y Diseño (Chile)es
dc.date.accessioned2023-01-19T19:54:38Z
dc.date.available2023-01-19T19:54:38Z
dc.date.issued2021
dc.descriptionTesis (Magíster en Hábitat Sustentable y Eficiencia Energética) -- Universidad del Bío-Bío. Concepción, 2021.es
dc.description.abstractExiste una alta demanda de atenciones médicas en los servicios de urgencia de carácter público principalmente, generando hacinamiento del recinto, debido a que los espacios de espera no dan abasto al gran número de personas que recurren a ellos. Bajo esta premisa, se evaluarán los caudales de ventilación de las salas de espera de los centros de salud del Gran Concepción, ya que, al ser una zona costera, permite utilizar la ventilación natural como recurso para mejorar la ventilación y calidad del aire interior. Para ello, se realizó un estudio tipológico de las salas de espera, con el fin de identificar aspectos de diseño arquitectónico, y posteriormente generar el cálculo numérico de las renovaciones de aire hora considerando posibles escenarios de ocupación. Los resultados de los requerimientos obtenidos, fueron que la mayoría de las salas de espera que presentan altos valores de demanda de ventilación, se deben a la falta de estrategias pasivas en su diseño arquitectónico, es decir, no se aprovecha al máximo el recurso natural existente, implicando el uso exclusivo de energía en ventilación forzada. Por tal motivo, se proponen mejoras viables a la infraestructura existente simuladas en el programa Optivent 2.1. demostrando que el efecto de algunas modificaciones en la morfología mejora la ventilación naturales
dc.description.abstract-2There is a high demand for medical attention in emergency services of a public nature, mainly, generating overcrowding of the premises, because the waiting spaces do not supply the large number of people who use them. Under this premise, the ventilation flows of the waiting rooms of the health centers of Greater Concepción will be evaluated, since, being a coastal area, it allows the use of natural ventilation as a resource to improve ventilation and indoor air quality. To do this, a typological study of the waiting rooms was carried out, in order to identify architectural design aspects, and then generate the mathematical calculation of the air renewals per hour considering possible occupation scenarios. The results of the requirements obtained were that most of the waiting rooms that present high ventilation demand values are due to the lack of passive strategies in their architectural design, that is, the existing natural resource is not used to the maximum involving the exclusive use of energy in forced ventilation. For this reason, viable improvements to the existing infrastructure simulated in the Optivent 2.1 program are proposed. demonstrating that the effect of some modifications in morphology improves natural ventilation.en
dc.description.call-numberT(E) 720.47 Ar69 2021es
dc.identifier.urihttp://repobib.ubiobio.cl/jspui/handle/123456789/3877
dc.language.isoeses
dc.subjectVENTILACIONes
dc.subjectCALIDAD DEL AIRE INTERIORes
dc.subjectCENTROS DE SALUDes
dc.subjectCARGA OCUPACIONes
dc.subjectVENTILACION NATURALes
dc.titleVentilación natural y calidad del aire en espacios de urgencia de centros de saludes
dc.typeTesises
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Arriagada_Soto_Javiera_Paz.pdf
Tamaño:
6.27 MB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: